Geometric twist calculation for flats and squares

For results, click on the grey box.


 The Lucefin Group - Production and distribution of cold-finished, hot-rolled, cold-drawn, forged steels
  Insert data:    
Width
Thickness    
      Results:
Allowed deviation degree / m   Corresponding deviation mm / m
Allowed deviation mm / m     Corresponding deviation degree / m


image020.gif, 5 kB Hot rolled
The Standard EN 10059 admitted:
4° to the meter for squares > 8 < 14 mm
3° to the meter for squares > 50 mm


Cold drawn
The Standard UNI 10233 pt. 2 admitted 4° to the meter