User:   Password:
 
  Back to index


Additional symbols

ex. 42CrMo4+QT = Quenched and Tempered   --  UNI 10440/00 - EN 10027-1/05    --
     
symbol other definition
+A  TC Soft annealing
+AC   Spherodized annealed
+AR   Raw for rolling, natural state
+AT   Solubilization annealing
+BC   Hot formed and sandblasted
+BG   Spheroid annealing (not laminar)
+BK   Bright Down, no heat treatment after drawing
+C   Cold-drawn
+CC   Semi-finished from continuous casting not subject to subsequent forming
+Cnnn   Cold-drawn to obtain nnn N/mm2
+CH   Core Hardenability
+CR   Cold rolled
+DC   Condition of supply selected by supplier 
+FP   Treated for ferrite-pearlite structure and hardness
+GBK   Annealed in protected atmosphere (ex. bright annealing)
+GKZ   Spheroid annealing (not laminar)
+H    Normal hardenability at maximum range
+HH    Hardenability restricted towards top
+HL    Hardenability restricted towards bottom
+HC   Hot rolled and cold drawn
+HR   Treated for a certain range of hardness
+HW   Normal state of hot forming
+I   Isothermal annealing
+LC   Skin pass (flattened or cold drawn)
+M   Thermo-mechanically rolled
+MA    Machined
+N TD Normalized
+NBK   Normalized in a controlled atmosphere
+NT   Normalized and Tempered
+P   Hardened by precipitation
+PE   Peeled
+PI   Hot formed and pickled
+PL   Polished (smoothed)
+Q   Quenched 
+QA   Quenched in air
+QO   Quenched in oil 
+QT TF Quenched and Tempered
+QW   Quenched in water 
+RA   Recrystallization annealing
+S   Annealed for cold shearing
+SH   Peeled reeled
+SL    Ground
+SR   Stress relieved 
+T   Tempered 
+TH   Tempered to obtain a range of hardness
+U   Untreared ex. St 52.3 U
+WW   Hot forming
 +V   (Vergüten) Hardening and tempering
+Z15   Through tickness property, minimum reduction of area = 15%
+Z25   Through tickness property, minimum reduction of area = 25%
+Z35   Through tickness property, minimum reduction of area = 35%
J2   Guaranteed impact strength at           –20°C > 27J (cold-drawn excluded)
J0   Guaranteed impact strength at               0°C > 27J (cold-drawn excluded)
JR   On request, guar. imp. strength at     +20°C > 27J (cold-drawn excluded)
K2   Guaranteed impact strength at           –20°C > 40J (cold-drawn excluded)
  Guaranteed impact strength at           –50°C > 27J (cold-drawn excluded)
G1    Rimming steel allowed
G2    Rimming steel not allowed
G3    Fully killed steel
FU   Rimming steel allowed
FN   Rimming steel not allowed
FF   Fully killed steel
G4   State of supply at producer's discretion
….E   ex. C45E  with max sulphur content specified
….R   ex. C45R with a range of sulphur content specified
R….   ex. RSt 52.3 killed steel
RR….   ex. RRSt44-3 special killed steel
U….   ex. USt 52.3 rimming steel
X….   ex. X 6Cr17 indicates steels with at least one alloy of more than  5%
BS   Base steels
QS   High quality steels
H   Cable profile
KG    Use at ambient temperature
N   Use at ambient temperature
KT    Use to low temperatures
NL   Use to low temperatures
KW    Use at high temperatures
NH   Use at high temperatures
R   Room temperature
GC   Suitable for cold drawing
+A      coating Hot dip aluminium coating
+AS   Aluminium-silicon alloy coating
+AZ   Aluminium-zinc alloy coating (>50% Al)
+CE   Electrolytic chromium/chromium oxide coating ECCS
+CU   Copper coating
+IC    Inorganic coating
+OC   Organic coating
+S     coating Hot dip tin coating
+SE   Electrolytic tin coating
+T      coating Hot dip lead-tin alloy (
+TE   Electrolytic lead-tin alloy (terne) coating
+Z   Hot dip zinc (galvanized) coating
+ZA   Hot dip zinc-aluminium coating (>50%Zn) 
+ZE   Electrolytic zinc coating
+ZF   Hot dip zinc-iron (galvannealed) coating
+ZN   Electrolytic zinc-nickel coating
m   ex. Cm 55 with a range of sulphur content 0.020-0.040%
….K     ex. St 37-3 K = kaltgezogen,  cold-drawn, drawn  ex. CK 15 = Fully Killed
….K     ex. C15K = cold-drawn
P BS 970 pt. 1 1991 Tensile strength N/mm²  550-700  
Q BS 970 pt. 1 1991 Tensile strength N/mm²  625-775
R BS 970 pt. 1 1991 Tensile strength N/mm²  700-850
S BS 970 pt. 1 1991 Tensile strength N/mm²  775-925
T BS 970 pt. 1 1991 Tensile strength N/mm²  850-1000
U BS 970 pt. 1 1991 Tensile strength N/mm²  925-1075
V BS 970 pt. 1 1991 Tensile strength N/mm²  1000-1150
W BS 970 pt. 1 1991 Tensile strength N/mm²  1075-1225
X BS 970 pt. 1 1991 Tensile strength N/mm²  1150-1300
Y BS 970 pt. 1 1991 Tensile strength N/mm²  1225-1375
Z BS 970 pt. 1 1991 Tensile strength N/mm² =1550

Top

Back

 
© 2007 Lucefin S.p.a - All rights reserved  |  P.Iva 01535340986  |  Disclaimer  |  Credits  |  Sales conditions